VIGIL3 Audio Input

Flexible, straight-forward solution for adding audio inputs to a VIGIL3 voice Alarm system

VIGIL3 is our latest generation of Voice Alarm system. Fully modular and expandable is the perfect Voice Alarm system for very small buildings, to much larger venues where at very large scale systems are required.

The Audio Input modules add to the flexible nature of a VIGIL3 system.

The BV3AIM2 (2 input) and the BV3AIM4 (4 input) modules are fitted to the back of a system rack enclosure and are added in multiples according to the user’s needs.

The inputs enable connection of multiple VIGIL inputs, in any combination, including our large format GUI, the touchscreen microphone, fire microphone and paging microphone to a VIGIL3 voice alarm system.

Each input has adjustable six band parametric equalisation and programmable prioritisation. Due to the engineer-friendly (and user-friendly) design of the VIGIL3 system, it is possible to configure all the audio inputs from a single location, anywhere on the network.

The modular design of the VIGIL3 means that an installed system can be altered and/or added to should a user’s requirements change. This includes the ability to increase the number of input modules and, thereby, microphones or any of our other VIGIL3 input options – providing true flexibility.

 

Features:
  • Available in either two or four input variations
  • DIN rail mounted within the rack
  • Each input has six-band parametric EQ
  • All inputs have programmable prioritisation
  • All inputs consist of a transformer-isolated audio input and have a RS485 connection for control data
  • Each unit is connected to the Ethernet network ring
  • It is possible to configure each audio input from any location on the network
  • Each module incorporates a VOX to allow for automatic audio broadcast when present
  •  

BV3AIM2 / BV3AIM4
Audio input module
2 inputs / 4 inputs
DIN rail mounted
111mm x 129mm x 55mm / 111mm x 129mm x 75mm
0.36 kg / 4 kg

Safe & Compliant

EN54 Certified

BS EN 54: Fire Detection & Fire Alarm Systems, is a mandatory standard that specifies requirements and laboratory testing for every component of fire detection and fire alarm system.

UKCA UK Conformity Assessed

UKCA (UK Conformity Assessed) marking on products replaces CE marking in the UK and requires that certification of construction products, such as VACIE / Voice Alarm Control & Indicating Equipment is performed by a UK-based approved body.

British Standards BS5839-8 Code of Practice
BS 5839-8 is a BSI Standards Publication code of practice providing recommendations for the design, installation, commissioning, and maintenance of voice alarm systems that automatically broadcast speech or warning tones, in response to signals from their associated fire detection and fire alarm systems.

Key Benefits

VIGIL3 Voice Alarm System

Fast. Powerful. Flexible. VIGIL3 is built with a fault-tolerant ethernet backbone, no ethernet switches are required and there are no licence fees. From a single rack to large distributed systems with hundreds of outputs, use wall mount or rack mount for outputs in any combination.

Documentation & Downloads

Looking for something in particular?

Search our full database of downloads and documentation

YEAR WARRANTY 7

Added peace of mind with our 7-Year Warranty*

When it comes to the systems you rely upon to keep lives safe, complete confidence is the very least you should expect. That's why all new manufactured Baldwin Boxall products come with a manufacturer 7-year warranty as standard.
Learn More
7 Year Warranty

VIGIL3 Product Range

Voice Alarm

VIGIL3 Amplifiers

Transformerless amplifiers, modular, energy-efficient and powerful. Range includes dual & quad amplifier options.

Voice Alarm

VIGIL3 Battery Charger

Compact module continually monitors system backup batteries & charges them whenever necessary.

Voice Alarm

VIGIL3 Audio Output Module

With VIGIL3 there is no need for the conventional ‘router-style’ control. Supports up to 8 audio outputs – network up to 100 units.

Voice Alarm

Powerful stand-alone, wall-mounted PAVA system. Ideal for fitting into building risers or places where space is limited.

Voice Alarm

VIGIL3 Audio Input Module

6-band parametric EQ and programmable priority for each input. Configure every input from a single point on the VIGIL3 network.

Voice Alarm
Built on a dedicated, fault-tolerant, Ethernet backbone with a range of networking options.
Voice Alarm

VIGIL3 Line Monitoring

All critical signal paths of a voice alarm system must be fully monitored & faults automatically indicated on key parts of the system.

Audio Loudspeakers

Loudspeakers

Powerful high-clarity loudspeakers for public address and voice alarm systems for both indoor and outdoor installations.

Microphones for Voice Alarm (VA) & Public Address (PA)

Touch Control

User-configurable, large format touchscreen Graphical User Interface (GUI) enables graphical control of our VIGIL3 and Eclipse5 systems. Upload logos, background images, edit buttons and much more.

Touch Control

Easy-to-use microphone with a touch sensitive screen for full control of a VIGIL3, VIGIL2, Eclipse4 or Eclipse5 system. Multi-function: NFC log in, select & route background music, emergency control mode and more. 

Fire Microphones

Baldwin Boxall Emergency Fire Microphones are housed in a robust, lockable steel enclosure and include a rugged, fist-held microphone console. Wall mountable and rack mounting units available.

Paging Microphones

BDM400 range of intelligent PA microphones with a variety of features to suit all installations. Suitable for connection to any of our voice alarm or public address systems – including VIGIL3 & Eclipse5.

Ambient Microphones

Ambient Noise Sensors (ANS) continually monitor the noise level (in a zone/area) and automatically adjust the volume of system broadcasts to that area – thus ensuring audibility at all times. Connect as part of any of our voice alarm systems.

Room Panels

Control Panels enable local control of audio facilities such as volume adjustment, music source selection and microphone input.

Make An Enquiry

Make An Enquiry (#13)
Scroll to Top
Our Revolutionising New EVC System

OmniCALL

Streamline protocols with unmatched connectivity, versatility, and sustainability.